UniFi Switch 7.5.10
Overview
UniFi Switch 7.5.10 includes the below improvements and bugfixes and is currently available for the models listed below.
- USW-Flex-XG | USW-Enterprise-8-PoE
- USW-Pro-XG-24/48-PoE | USW-Pro-XG-24/48 | ECS-24/48-PoE | USW-Pro-XG-Aggregation
- EAV-XG-24-PoE | EAV-Fiber
- USW-Aggregation
- USW-Pro-8-PoE | USW-Pro-Max-16/24/48-POE | USW-Pro-Max-16/24/48
- USW-Pro-HD-24-PoE | USW-Pro-XG-8/10-PoE
- USW-16/24/48-POE | USW-24-48 | USW-Lite-8/16-POE | USW-Mission-Critical
- USW-Flex
Β
Test & ConfirmΒ - Automatically reverts changes if connectivity to the switch is lost after configuration updates.
- Requires UniFi Network Application 10.5.67 or newer.
Power Port SequencingΒ - Staggers PoE port power-up during switch restarts, reducing power surges and improving stability.
- Requires UniFi Network Application 10.5.67 or newer.
- Not currently available on the USW-Enterprise-8-PoE.
Link DebounceΒ - Reduces link flapping caused by brief interruptions and unstable connections.
- Requires UniFi Network Application 10.5.67 or newer.
Improvements
All Models
- Improved device connectivity stability through more resilient management configuration handling.
- Improved reporting to prevent incorrectly logged STP state and link flapping events.
- Improved SFP auto-negotiation reliability for DACs, fiber modules, and RJ45 SFP modules.
Pro-Max, Pro (8-PoE, XG-8/10-PoE, HD-24), USW-16/24/48, Lite-8/16-PoE, US-16-XG
- Added support for Energy Efficient Ethernet (EEE) to reduce power consumption on supported ports.
Pro-Max, Pro (8-PoE, XG-8/10-PoE, HD-24)
- Expanded custom MAC and IPv4 ACL capabilities to 512 entries.
USW-Flex
- Improved topology accuracy.
Bugfixes
All Models
- Fixed brief traffic interruptions that could occur when VLAN networks were added or removed.
- Fixed RADIUS Auto/MAC authentication to correctly assign IP addresses to VoIP phones on the Voice VLAN.
- Fixed Storm Control settings not syncing across Link Aggregation groups.
- Fixed an issue where 802.1X MAC-based sessions would not time out after exceeding the configured idle timeout.
- Fixed an issue where 802.1X MAC-based authenticated clients could lose network access after the idle timeout expired.
Pro-Max, Pro (8-PoE, XG-8/10-PoE, HD-24), USW-16/24/48, Lite-8/16-PoE, Aggregation
- Fixed an issue where 1 Gbps copper SFP modules could fail to establish a link after hot-plugging.
- Fixed an issue where RADIUS accounting did not work correctly.
- Fixed an issue where guest MAC entries did not expire on 802.1X MAC-based ports.
- Fixed an issue where forwarding failed when multiple Virtual Network Override devices were connected to the same port.
- Fixed an issue where Virtual Network Override and Dynamic VLAN Assignments did not adhere to the port VLAN configuration.
- The VLAN must now be included in the Tagged VLANs configured on the port.
Pro-Max, Pro (8-PoE, XG-8/10-PoE, HD-24)
- Fixed a missing default route after creating or removing an L3 network.
Pro (24/48, Aggregation), Enterprise (24/48-PoE, XG-24)
- Fixed an issue where 25 Gbps Link Aggregation links did not establish after a cold boot.
- Fixed an issue where clients could not authenticate using 802.1X EAP-TLS.
- Fixed an issue where allowed MAC addresses on MAC-restricted ports could not access the network after a reboot.
USW-48-PoE
- Fixed an issue where 802.1X MAC-based authentication and fallback VLAN assignment could fail when DHCP Guarding was enabled.
USW-Aggregation
- Fixed an issue where the touchscreen did not initialize after a firmware upgrade.
EAV (Fiber, XG-24-PoE), ECS-24/48, Pro-XG (24/48, Aggregation), Enterprise-8, Flex-XG
- Fixed an issue where the switch could unexpectedly reboot or go offline while applying configuration changes.
- Fixed an issue where 802.1X MAC-based EAP-TLS authentication did not work correctly.
- Fixed an issue where 802.1X-authenticated clients could not access the network when using RADIUS-assigned VLANs without a VLAN assignment.
- Fixed an issue where 802.1X multi-host mode was not applied correctly after port mode changes.
- Fixed an issue where VLAN leakage could occur on 802.1X-authenticated ports when using RADIUS-assigned VLANs.
- Fixed an issue where Voice VLAN-tagged traffic could be forwarded to an 802.1X-authenticated client.
- Fixed an issue where multiple Port Mirroring configurations did not take effect.
- Fixed an issue where link instability and packet loss could occur with directly connected Intel I219-V NICs and Cisco Meraki access points.
- Fixed a missing Default Gateway IP setting in Layer 3 DHCP configuration.
- Fixed an issue where DHCP Snooping could prevent devices from obtaining an IP address after a reboot.
EAV (Fiber, XG-24-PoE)
- Fixed an issue where PTP time synchronization did not start after a reboot.
Known issues
- XG-6-PoE,Β Pro (24/48-PoE), Enterprise (24/48-PoE):Β The last PoE port may fail to power the connected device when the switch is rebooted. To recover, disable PoE on the affected port using the Port Manager, wait a few seconds, and then re-enable PoE.
Additional information
- Touchscreen and Etherlighting may take several minutes to become operational after the firmware update.
Β
If you encounter any issues with this release, please provide us with some details on your setup and include the following information:
- Switch model(s)
- Previous Switch release version
- UniFi Network application version